FD30 vs FD30S vs FD60 Fire Doors Explained

FD30 vs FD30S vs FD60 comes down to two things: how long a door holds back fire, and whether it also stops smoke. Read on to learn what each code means, where each one is used and how to tell what rating your own door has.

Updated 7 min read By the Fire Door Specialist team

The short answer

  • FD means fire door. The number is the minutes it held back fire in a lab test.
  • FD30 holds back fire for 30 minutes. FD60 holds it back for 60 minutes.
  • The S means smoke seals. An FD30S also limits the cold smoke that gets past it.
  • Most homes, flats and offices use FD30 or FD30S. FD60 is used where the fire strategy needs more time, such as some stair cores and plant rooms.
  • The rating only counts if the whole doorset is fitted and kept as it was tested.

FD30 vs FD30S vs FD60: What the Codes Mean

Every fire door rating follows the same pattern. “FD” stands for fire door. The number is how many minutes the door held back fire in a lab test. An “S” on the end means it also has smoke seals.

Fire door ratings compared: FD30, FD30S, FD60, FD60S, FD90 and FD120

So FD30 is a 30-minute fire door, FD30S is a 30-minute fire door with smoke seals, and FD60 is a 60-minute fire door. FD90 and FD120 exist, but they are rare in homes and offices.

What Does FD30 Mean on a Fire Door?

An FD30 door kept fire from getting through for at least 30 minutes in a standard furnace test. That is called integrity: no flames or hot gas passing through the door or round its edges.

Thirty minutes is enough for most buildings, as it gives people time to escape and firefighters time to arrive. That is why most internal fire doors in homes, flats, HMOs, schools and offices are FD30.

What Does the S in FD30S Mean?

The S means the door has smoke seals and has passed a test that limits how much cold smoke leaks past it. Smoke seals are usually brushes or rubber fins set into the frame or door edge.

This matters because smoke, not flame, causes most harm in a fire. In the early stages, before the intumescent strips have swollen, cold smoke can drift through the gaps and fill an escape route. Smoke seals stop that.

Parts of a rated fire door: self-closer, rating label, intumescent strip, smoke seal, hinges, glass and gaps

You will often see FD30S on flat front doors, doors onto shared stairs, kitchen doors in HMOs and doors along escape corridors.

When Do You Need an FD60 Fire Door?

An FD60 door holds back fire for at least 60 minutes in the test. It is used where a building’s fire strategy needs more time, for example to protect a stair that is the only way out of a tall building.

  • Doors between fire compartments in larger buildings.
  • Some doors onto protected stair cores and lift lobbies.
  • Plant rooms, boiler rooms and some electrical rooms.
  • Some doors onto service risers and stores.

You cannot choose FD60 just to be safe in every case. The rating should match the building’s fire strategy, which comes from Building Regulations and the fire risk assessment. Fitting the wrong rating can still leave you non-compliant.

FD30, FD30S and FD60 Fire Doors Compared

FD30 vs FD30S vs FD60
FD30FD30SFD60
Fire resistance30 minutes30 minutes60 minutes
Smoke sealsNoYesOnly if FD60S
Typical usesMost internal fire doorsFlat front doors, stair and kitchen doorsStair cores, plant rooms, compartment walls
Typical thicknessAround 44 mmAround 44 mmAround 54 mm
Guide price, supplied and fitted£550–£950£1,100–£1,900 as a flat front door£800–£1,300

Thickness varies by maker. Prices are guide prices before VAT and depend on size, glass and hardware.

Which Fire Door Rating Does Your Door Need?

Typical fire door ratings by location
Typical fire door ratings by location
DoorTypical ratingNotes
Flat front door onto a shared stair or corridorFD30S, self-closingProtects the shared escape route
HMO bedroom door onto the escape routeFD30 or FD30S, self-closingCouncil licence conditions decide
HMO or flat kitchen doorFD30S, self-closingKitchens are where most house fires start
Office corridor or cross-corridor doorFD30SOften on hold-open devices
Hotel bedroom doorFD30S, self-closingGuests sleep in unfamiliar buildings
Stair core door in a tall buildingFD30S or FD60SSet by the fire strategy
Plant room or boiler roomOften FD60Higher fire load behind the door
House with one familyOften noneExcept some loft conversions and garage doors

Always follow your building’s fire strategy or fire risk assessment. For shared houses, see HMO fire door requirements.

How Fire Door Ratings Are Tested

Fire doors are tested in a furnace as a complete doorset: door, frame, hinges, seals, glass and hardware together. The result only covers that exact set-up.

Fire door test standards in the UK
StandardWhat it testsHow results are shown
BS 476-22Fire resistance (the British standard)FD30, FD60 and so on
BS EN 1634-1Fire resistance (the European standard)E30, E60, or EI30 if insulation is also met
BS 476-31.1Smoke leakage (the British standard)Adds the S, as in FD30S
BS EN 1634-3Smoke leakage (the European standard)Adds Sa, as in E30 Sa

Most fire doors sold in the UK are also third-party certified, for example under BM TRADA Q-Mark or Certifire. Certification checks that every door made matches the one that passed the test.

How to Tell a Fire Door’s Rating

  1. 1

    Look for a label or plug

    Most certified fire doors have a label or coloured plug on the top or hinge edge. It names the scheme and the rating.

  2. 2

    Check the paperwork

    New doors should come with a certificate and fitting instructions. Ask the fitter or the previous owner.

  3. 3

    Look at the seals

    A continuous strip round the edges suggests a fire door. A brush or fin seal suggests an S rating.

  4. 4

    Ask an inspector

    If there is no label and no paperwork, a trained inspector can check the door and advise on certifying or replacing it.

FD30, FD30S and FD60 Fire Door Costs

Fire door supply and fit prices
ItemGuide priceCharged
FD30 internal doorset, supplied and fitted£550–£950per door
FD30S flat entrance doorset, supplied and fitted£1,100–£1,900per door
FD60 doorset, supplied and fitted£800–£1,300per door
Made-to-measure FD30 doorset, fitted£900–£1,800per door
Made-to-measure FD60 doorset, fitted£1,200–£2,400per door
Fire door leaf into a sound, matched frame£350–£650per door

Guide prices before VAT, last checked October 2026. Your quote is fixed after a visit or survey.

Glass panels, special finishes, security locks and non-standard sizes all add to the price. See fire door installation in London and made-to-measure fire doors in London.

Fire Door Rating Myths

“A thick door is a fire door”

A solid door is not a fire door unless it was tested and certified. Weight alone proves nothing.

“FD60 is always safer”

FD60 is only needed where the fire strategy asks for it. Fitting it badly is worse than a well-fitted FD30.

“Any hinges will do”

Hinges, closers, locks and glass must all be allowed by the door’s test evidence, or the rating is lost.

“The rating lasts forever”

Damage, gaps, painted seals and missing closers can make any rated door fail. Regular checks keep it working.

Fire Door Rating Questions

How is an FD30 door different from an FD60 door?

An FD30 door held back fire for at least 30 minutes in a lab test, and an FD60 for at least 60 minutes. FD60 doors are usually thicker, heavier and dearer. They are used where the building’s fire strategy needs more time, such as some stair cores.

What does the S mean in FD30S?

The S means the door has smoke seals and has passed a test that limits cold smoke leaking past it. Smoke seals stop smoke spreading in the early stages of a fire, before the intumescent strips swell.

Is FD30S better than FD30?

It gives the same fire resistance, plus protection against cold smoke. On escape routes, flat front doors and kitchen doors, FD30S is usually what is needed. Inside rooms off a protected route, FD30 may be enough.

Do flat front doors need to be FD30S?

In most blocks of flats and converted houses, yes. The flat front door protects the shared escape route from a fire in the flat, so it is usually expected to be a self-closing FD30S door.

What is E30 Sa?

E30 Sa is the European way of writing a similar rating to FD30S. E30 means 30 minutes of integrity under BS EN 1634-1, and Sa means it passed the smoke leakage test under BS EN 1634-3.

Can I upgrade an FD30 door to FD60?

Not usually. A fire door is tested as a whole set, and adding parts to an FD30 door does not make it FD60. If a door needs to be FD60, it should be replaced with a certified FD60 doorset.

How long does an FD30 door last in a real fire?

It depends on the fire and the door’s condition. FD30 means it met the 30-minute standard in a test. A well-kept door in good condition should perform close to that. Gaps, damage or missing closers can make it fail much sooner.

How thick is an FD30 fire door?

Most FD30 doors are around 44 mm thick and most FD60 doors around 54 mm, but it varies by maker. Thickness alone does not prove a rating, so always check for a label or certificate.

Not sure what you have?

Find Out What Your Fire Doors Need

Tell us about the building. We will check each door’s rating, tell you what it should be and give you a fixed price for any work.

  • Ratings checked door by door
  • Certified doorsets supplied and fitted
  • Labels and records for every door
Ask about fire door ratings07760 499 014

Get your fire door quote

A few quick questions. We reply the same working day.

Step 1 of 5

What type of building?
How many doors?
When do you need us?
Anything else we should know?

Optional. Skip this if there is nothing to add.

Where should we send your quote?

No obligation. Your details are only used to reply to you. Privacy policy