Do hotel bedroom doors need to be fire doors?
Yes. Guest room doors that open onto a corridor should be fire doors that close on their own. They protect the corridor so other guests can get out safely. Most also need smoke seals and a closer that shuts the door from any angle. That way a guest cannot leave the door open by mistake.
How often should hotel fire doors be inspected?
BS 9999 suggests at least every 6 months. Many hotels check guest room and corridor doors every 3 months on a rolling plan, because the doors wear so quickly. A rolling plan means you check a few floors at a time. Every door gets checked several times a year, and no floor ever has to close.
How much does a hotel fire door inspection cost?
Hotels are usually priced at £20–£40 per door for larger properties and £35–£65 per door for smaller ones, before VAT. Hold-open tests are £15–£35 per device. Spreading the work across a rolling plan also spreads the cost across the year, which many hotels find easier to budget for.
Can you inspect without closing rooms?
Yes. We check rooms after check-out and before the next guest arrives. Corridor doors are checked during quiet hours, so no floor needs to close. We work with housekeeping, so rooms are checked while they are being cleaned. That keeps the inspection out of sight of guests.
Why do hotel fire doors slam?
Usually because the closer was turned up to make sure doors latch. A closer can be set to close fully without slamming, which keeps guests happy and the door safe. Slamming doors disturb guests and damage frames. A short service visit can fix the closer speed and stop complaints.
Can hotel room doors have security chains?
Yes, if the chain or viewer is fire rated and fitted as the door maker allows. Ordinary fittings can leave weak spots in the door. We check every chain, viewer and lock as part of the inspection, and note any that could weaken the door. If a fitting is not rated, it can usually be swapped for one that is, without replacing the whole door.
Who is responsible for hotel fire doors?
Under the Fire Safety Order 2005, it is the Responsible Person. That is often the hotel owner or the firm that runs it. The general manager usually looks after it day to day. In franchise hotels, the franchise owner and the operator may share the duty. Make sure your contracts say who checks the doors.
What rating should hotel room doors have?
Most guest room doors should be FD30S, which means 30 minutes of fire resistance with smoke seals. Doors to stairs and some service areas may need a higher rating. Your fire risk assessment sets the right rating for each door in the hotel. You can usually find the rating on a label on the top or hinge edge of the door. If you cannot find it, we can trace it for you.
Do hotel corridor doors need to be fire doors?
Many do. Long hotel corridors are often split into sections by fire doors, which stop smoke from filling the whole floor. These doors may be held open on the fire alarm, so they must close fully when it sounds. Housekeeping carts and luggage often knock these doors, so they need regular checks for gaps and damaged seals.
What should hotel staff check every day?
Staff should look out for doors wedged open, closers that do not shut the door and damaged seals. Housekeeping teams are well placed to spot these, as they open every room door each day. Report faults quickly so they can be fixed before the next guest.